Relays: Operation, Specifications, and Applications

d’oct. 30 2025
Source: DiGi-Electronics
Browse: 906

A relay is an electrically operated switch used to control high voltage or high current using a small signal. It provides electrical isolation between control and load circuits, improving safety and reliability. Relays are used in power systems, machines, vehicles, and automation. This article explains how relays work, their parts, types, ratings, applications, failures, and design tips in detail.

Figure 1. Relays

Relay Overview

A relay is an electrically operated switch designed to allow a small, low-power current to control a much larger current, making it a basic component in modern electrical and electronic circuits. This capability is required in applications where direct control of high-voltage or high-current devices could pose safety risks or reduce efficiency. By isolating the control side from the power side, relays protect sensitive low-power circuits from voltage spikes, surges, and other potentially damaging electrical stresses. Beyond safety, relays enable automation, allowing controllers, microcontrollers, and sensors to reliably operate heavy loads such as motors, lighting systems, HVAC units, and industrial machinery.

Functions of Relay

Figure 2. Functions of Relay

A relay is a type of switch that uses electricity to control other electrical circuits. Inside a relay, there is a coil of wire. When electricity flows through the coil, it creates a magnetic field. This magnetic field pulls a small metal piece called an armature, which moves and changes the position of the contacts. The contacts are either closed to allow electricity to pass through or open to stop the flow.

The process works in steps:

• Coil receives electricity - magnetic field forms.

• Armature moves - contacts switch on or off.

• Coil turns off - a spring moves the armature back to its starting position.

Components of a Relay

Figure 3. Components of a Relay

Relay is an electrical switch that uses an electromagnet to operate. The main inductive part is the Coil & Core, which generates a magnetic force when an electrical current creates a magnetic field. This assembly is often protected by a Housing.

The mechanical switching mechanism includes the Armature, which moves in response to the magnetic force and provides a mechanical bias for operation. A Spring works to restore the armature to its original position when the magnetic field is removed; this spring is often made of a silver alloy for conductivity.

The electrical switching action occurs at the contacts: the Moving Contact is physically moved by the armature to connect or disconnect circuits, while the Fixed Contacts (NO/NC) represent the relay's normally open (NO) or normally closed (NC) state, determining the circuit's default connection.

Relay Coil Specifications

ParameterWhat It MeansExample (5 V Relay)
Coil ResistanceThe resistance of the coil, calculated as voltage divided by current.R = 5V ÷ 0.07A = 71Ω
Coil PowerThe amount of electrical power the coil uses, calculated as voltage times current.P = 5V × 0.07A = 0.35W
Pull-In VoltageThe voltage at which the relay starts to switch on. Usually around 75–80% of the rated voltage.3.8–4 V
Drop-Out VoltageThe voltage below which the relay turns off. Usually around 10–30% of the rated voltage.1–1.5 V

Relay Contact Switching

Figure 4. Relay Contact Switching

AC Switching

When switching AC loads, the current naturally passes through zero in each cycle of the alternating current. This helps stop electrical arcs that can form when contacts open, making AC switching easier and less damaging to the relay contacts.

DC Switching

Figure 5. DC Switching

DC is constant and does not pass through zero. This makes it more likely for an arc to form when contacts open. These arcs can damage or weld the contacts, so special care is needed when using relays with DC loads.

Methods to Prevent Arcing

• Flyback diodes: Commonly used for DC loads to safely redirect current.

• RC snubbers: Used for both AC and DC to limit voltage spikes.

• Metal oxide varistors (MOVs): Suppress high voltage transients and protect contacts.

Common Relay Types and Their Applications

Relay TypeAdvantagesTypical Applications
Electromechanical Relay (EMR)Cost-effective, provides clear electrical isolation between control and load circuitsUsed in industrial controls, home appliances, and automotive systems
Reed RelayFast switching speed, compact size, sealed for protection, and suitable for low-current signalsCommonly used in communication devices, test instruments, and signal routing systems
Solid-State Relay (SSR)No moving parts, silent operation, high switching speed, and long lifespanBest for automation, heating systems, and applications needing frequent switching
Latching RelayMaintains its position even after power is removed, energy-efficientUsed in memory circuits, battery-powered systems, and remote control devices

Which is Better?

Each type of relay is best suited for specific situations, depending on the circuit's requirements. Electromechanical relays are simple and affordable, making them useful for many basic control systems. Reed relays are better when a fast response and low current operation are required since they switch quickly and are sealed for protection.

Solid-state relays are known for their quiet and efficient performance because they have no moving parts, making them suitable for circuits that need frequent switching. Latching relays help save energy since they can stay in one position without using continuous power.

Relay Failures and Their Solutions

Common FailureCauseFix / Preventive Measure
Contact Pitting or WeldingOccurs when excessive current or arcing damages the relay contactsUse contacts rated for the correct load and include arc suppression devices like snubber circuits
Coil BurnoutHappens when the coil is exposed to higher voltage or continuous overcurrentOperate within the rated coil voltage and use protective components to limit the surge
Contact Bounce or ChatterResults from vibration, poor mounting, or weak coil magnetic forceEnsure firm relay mounting, proper coil drive voltage, and quality relay design
Oxidation or CorrosionCaused by moisture, dust, or exposure to harsh environmentsUse sealed relays or relays with gold-plated contacts for low-current signals

Different Applications of Relays

• Headlights and fog lamps

• Starter motor control

• Motor starters

• Conveyor belt control

• Smart lighting control

• Appliance switching

• Overcurrent protection

• Earth fault protection

• Line switching

• Signal routing

• Speaker protection circuits

• Refrigerators (compressor relay)

• Washing machines

Conclusion 

Relays are basic for safe and reliable control of electrical circuits. Their ability to isolate signals, handle different loads, and support automation makes them useful in many systems. With correct selection, proper wiring, and good design practices, relays offer long service life and stable performance. Understanding their operation and specifications is required for building safe and efficient circuits.

Frequently Asked Questions [FAQ]

Q1. What is relay contact material?

It is the metal used on relay contacts, such as silver, gold, or tungsten. It affects conductivity, resistance to arcing, and contact life.

Q2. What is relay hysteresis?

It is the difference between the voltage that turns the relay on (pull-in) and the voltage that turns it off (drop-out). It prevents chattering.

Q3. Can one relay switch both AC and DC loads?

Yes, but the AC and DC ratings are different. DC loads are harder to switch and need lower voltage and current limits.

Q4. Why use a relay socket?

It allows easy relay replacement, protects relay pins from damage, and improves wiring safety.

Q5. What does SPDT or DPDT mean in relays?

These describe contact configurations. SPDT controls one circuit with two outputs. DPDT controls two separate circuits at the same time.

Q6. What is the difference between NO and NC contacts?

NO (Normally Open) contacts close when the relay is powered. NC (Normally Closed) contacts open when the relay is powered.